1812CAN Common Mode Choke | Coilcraft
Inductor Finders Power  |   RF
Power Magnetics Tools
RF Inductor Tools
CM Choke \ Ferrite Beads
LC Filter Designer
IC / Inductor Match Tool
Application Notes
Other Resources
Designer's Kits

1812CANbus
Common Mode Choke

  • Inductance values from 11 µH to 100 µH
  • Filters a broad frequency range of common mode noise
  • 50% lower DCR and higher current handling than other CANbus chokes in the market
  • Designed for common mode noise suppression on CAN or CAN FD
    in automotive or general industrial automation applications
  • 250 Vrms, 1 minute interwinding isolation (hipot)
  • AEC-Q200 Grade 1 (−40°C to +125°C)
  • Can be used for FlexRay automotive bus system
  • Low profile 1812 footprint: 4.95 × 3.18 × 3.0 mm
  • RoHS-compliant  260°C compatible. Silver-palladium-platinum-glass frit terminations.

SPECIFICATIONS

S-Parameters 3D model
Part number1
Click to get parts
Inductance2
±30 (µH)
DCR max3
(Ohms)
Irms4
(mA)
1812CAN-113NR_ 11 0.27 430
1812CAN-223NR_ 22 0.40 360
1812CAN-513NR_ 51 0.59 300
1812CAN-104NR_ 100 0.80 200
1 When ordering, please specify packaging code: e.g. 1812CAN-104NRC
Packaging: C = 7" machine-ready reel
EIA-481 embossed plastic tape (600 parts per full reel). Quantities less than full reel available: in tape (not machine ready) or with leader and trailer ($25 charge).
D = 13" reel, machine-ready 
EIA-481 embossed plastic tape. Factory order only, not stocked (2200 parts per full reel).
2 Inductance is per winding, measured at 100 kHz, 0.1 Vrms, 0 Adc using an Agilent/HP 4263B LCR meter and a Coilcraft CCF 1113 fixture.
3 DCR is specified per winding, measured 25°C on a Keithley 580 micro-ohmmeter and a Coilcraft CCF888 fixture. For other operating temperatures, use this DCR at Temperature calculator.
4 Max current that may be applied at +125°C
5 Ambient temperature range: −40°C to +125°C with Irms current.
6 Storage temperature range: Component: −40°C to +125°C
Tape and reel packaging: −40°C to +80°C
7 Resistance to soldering heat: Three reflows at >217°C for 90 seconds (+260°C ±5°C for 20 – 40 seconds), allowing parts to cool to room temperature between.
8 Electrical specifications at 25°C.
Refer to Soldering Coilcraft Components before soldering.
PCB washing: Tested to MIL-STD-202 Method 215 plus an additional aqueous wash. More info.

Your comments and suggestions are welcome. Contact [email protected]
Copyright © 2018, Coilcraft, Inc.   Privacy policy